CINV=0, HCMPON=0, CSTEN=0, CEG=00, CDFS=00, COE=0
Comparator Control Register
CINV | Comparator Output Polarity Selection 0 (0): Do not invert comparator output 1 (1): Invert comparator output |
COE | Comparator Output Enable 0 (0): Disable comparator output (output signal is low level) 1 (1): Enable comparator output |
CSTEN | Interrupt Select 0 (0): Output through the edge selector 1 (1): Output directly |
CEG | Selection of Valid Edge (Edge Selector) 0 (00): Do not detect edge 1 (01): Detect rising edge 2 (10): Detect falling edge 3 (11): Detect both edges |
CDFS | Noise Filter Selection 0 (00): Do not use noise filter 1 (01): Use noise filter sampling frequency of PCLKB/23 2 (10): Use noise filter sampling frequency of PCLKB/24 3 (11): Use noise filter sampling frequency of PCLKB/25 |
HCMPON | Comparator Operation Control 0 (0): Stop operation (comparator outputs a low-level signal) 1 (1): Enable operation (enables input to the comparator pins) |